How Koizuma Intense Pulsed Light (IPL) Handset Works

Koizuma IPL projects light pulses (with wavelength ranging between 550nm-1200nm) onto the skin. During the process, melanin in the hair absorbs the wavelengths of strong light pulses emitted from the device, thereby heating and damaging key areas of your hair follicle which stunts hair growth. After a few sessions, hair stops growing and prolonged usage can cause lasting results as light pulses stimulate the hair follicle to go into a resting phase.

The handset also stimulates regeneration of collagen and elastic fibre thereby, improves the colour and texture of the skin without surgery. It can treat some of the visible damage caused by sun exposure, which is most noticeable on face, neck, hands or chest. Koizuma helps even out the skin texture and colour, reduces wrinkles and skin rejuvenation.

  • Koizuma should not be painful, if you feel uncomfortable, reduce the light intensity setting.
  • After moving to another body area or recent tanning, perform a skin test to determine the right light intensity

General Conditions

The laser IPL treatment may not be as effective on individuals with dark skin as there is a higher concentration of melanin in darker skin tones as compared individuals with light skin. The treatment is not as effective on skin with high concentration of melanin due to the little contrast between skin colour and hair colour. This is because the melanin-rich skin cells can also absorb light from the IPL and heat up. This may cause pain, blister and even burns as IPL spreads onto the skin instead of being absorbed by hair follicles. Thus, laser and IPL devices works best on light to medium skin tones wit darker hair.

The Laser IPL treatment is also not as effective on blond, red, white and grey hair as they contain lower concentration of melanin. This is because IPL targets the melanin in hair follicle. Light hair follicles with low melanin concentration will not be able to absorb the IPL effectively. Melanin in darker hair tends to better absorbs light pulses from the device.

Treatment Process

1st Treatment (Week 0)

  • After first treatment, it can take 1 to 2 weeks for the hair to fall out.
  • During the initial treatments, you might still see some hair growing. These were likely to be hair in their growing phase during the first treatment.

2nd – 3rd Treatment (Week 2 & Week 4)

  • After 2-3 treatments, you should see a noticeable reduction in hair growth.

4th – 5th Treatment (Week 6 & Week 8)

  • After 4-5 treatment, you should see a significant reduction of hair growth in targeted areas.
  • Reduction in hair density may be visible. Continue frequent touch-ups (every 4 weeks) to maintain the result.

Prep Your Skin

  • Before zapping your hair away with the handset, remove all visible hair by shaving the targeted area.
  • Ensure there are no hair remaining above the skin surface. This allows the light to be easily absorbed by the melanin located in the hair roots and ensure effective treatment.
  • Do not wax, epilate or use depilatory cream which removes hair follicles from the roots which hinders the IPL process.
  • You are recommended to take a shower and pat skin dry before treatment to ensure the skin is free of oil, dirt.

Skin Test

  • Check skin tone table and adjust the intensity level according to the intensity level for each skin tone.

Selecting the right intensity

  • The device provides 8 different light intensities. You are recommended to set the appropriate intensity depending on your skin tone.
  • Press for 2 seconds to turn device ON and OFF.
  • Short press to adjust the light intensity level will increase from 1st mode to 8th After reaching 8th mode, the light intensity will decrease until 1st mode.
  • Press O and hold for 2 seconds to switch mode between “AUTO” and “MANUAL”.
  • Press O and , hold for 2 seconds to switch between hair removal (HR) mode and skin rejuvenation (SR) mode.

Handling Honey Laser IPL handset

  • Clean the light window before use
  • Insert the adapter head
  • Plug the power supply in the wall socket
  • Switch on the device and select the right light intensity for your skin tone
  • Place the device at a 90° angle on the skin so that the skin contact surface of the device is in contact with your skin.
  • Leave no gaps between the skin and device to ensure no light escape.
  • Press the device firmly onto your skin to ensure proper skin contact. Press O to release a flash. You will feel a warm sensation because of the flash.
  • Place the device (flash/light) window in full contact with the skin to make sure the product works correctly. If the device is not in proper contact with your skin, it will not work.
  • Place device on the next area to be treated. After each flash, it will take 1 to 3 seconds for the device to produce the next flash.
  • For a larger body area, use AUTO mode. Hold down the O button and treat along your targeted area. For smaller areas, use manual mode.
  • When you have finish the treatment, press and hold on  for 2 seconds to turn the device off.
  • Remove the adapter from the electric socket.
  • It is important to wipe the light window after use with alcohol each week for hygiene purposes.

Treatment schedule

  • In the first phase of your treatment, treat once a week for 4 to 8 weeks (depending on your skin result).
  • After this period, use your handset once a month, for 3 months or until satisfied.
  • To maintain hairless smooth skin, use your handset once every 2-3 months, or as needed.

Skin Rejuvenation schedule

  • Please note that for skin rejuvenation, use every 3 days.

After care

  • After the Koizuma treatment, you can safely apply lotion, creams or moisturiser on the treated area.
  • If you experience skin irritation or skin redness after the treatment, wait until it disappears before applying any product onto your skin.
  • If you experience skin irritation or redness after applying any product, gently wash off with water.

 Common reactions

  • If your skin shows slight redness and/or pickle, tingle or feel warm, the reaction is harmless and will disappear soon.
  • Dry skin and itching may occur due to shaving or a combination of shaving and IPL treatment. You can cool the area with ice or wet face cloth. If dryness persists, you can apply a moisturiser that is not scented on treated area.

Rare side effects

  • Burns, excessive redness (around hair follicle)
  • Skin discolouration; occurs very rarely
  • Epidermal heating

Device cleaning and storage

  • After use, switch OFF device, unplug it and let the device cool down
  • Use a soft cloth to clean the light window, the outside surface of the attachments and the reflectors on the side
  • Store device in a dust free and dry environment

Common reactions

  • If your skin shows slight redness and/or pickle, tingle or feel warm, the reaction is harmless and will disappear soon.
  • Dry skin and itching may occur due to shaving or a combination of shaving and IPL treatment. You can cool the area with ice or wet face cloth. If dryness persists, you can apply a moisturiser that is not scented on treated area.

Rare side effects

  • Burns, excessive redness (around hair follicle)
  • Skin discolouration; occurs very rarely
  • Epidermal heating

Device cleaning and storage

  • After use, switch OFF device, unplug it and let the device cool down
  • Use a soft cloth to clean the light window, the outside surface of the attachments and the reflectors on the side
  • Store device in a dust free and dry environment

Warnings

  • Do not use device if you are pregnant or breast feeding.
  • Do not use device if you have active implants.
  • Do not use device if you are taking any of the medications/treatment listed below:
  • If you have used Alpha-Hydroxy Acids (AHA), Beta-Hydroxy Acids (BHAs), tropical isotretinoin and azelaic acid within the past 1 week.
  • If you have consumed any form of isotretinoin Accutane or Roaccutane in the last 6 months. This treatment can make the skin more susceptible to tears, wounds and irritations.
  • If you are taking photosensitizing agents or medications, check if your medication can cause photo-allergic reactions, photo-toxic reactions or if you have to avoid the sun while taking the medicine.
  • If you take anti-coagulation medication which does not allow for a minimum of 1 week washout period prior to each treatment.
  • If you have undergone radiation therapy or chemotherapy within the past 3 months.
  • If you are on painkillers which reduces pain sensitivity.
  • If you are on immunosuppressive medications.
  • If you have had surgery in the targeted area in the last 3 weeks.

Do not use device if you are experiencing any of the medical conditions listed below:

  • Diabetes or other systematic metabolic diseases.
  • Congestive heart diseases.
  • Medical condition relating to photosensitivity.
  • Skin sensitivity which can easily develop rash or allergic reaction
  • Skin disease such as skin cancer or history of skin cancer in targeted area.
  • History of vascular disorder.
  • History of collagen disorder.
  • History of immunosuppressive disease.
  • Any bleeding disorder.

Do not use device if you are experiencing any of the skin conditions listed below:

  • Infection, eczema, burns, inflammation of hair follicle, open laceration, herpes, simplex (cold sores), wounds, lesions, and hematomas in the targeted area.
  • Irritated (red or cut), sunburned, recently tanned areas.
  • Areas such as moles, freckles, large veins, darker pigmented areas, scars and skin anomalies without doctor consultation.
  • Warts, tattoos or permanent makeup.

Do not use device in the areas listed below:

  • Around the eyes or near the eyebrows.
  • On the lips, nipples, areola, labia, minora, vagina, anus, inside nostrils, ears.
  • Men should not use device on the face and neck, including all beard growing areas nor genital areas.
  • Areas exposed to long lasting deodorants.
  • Over artificial silicone implants, subcutaneous injection ports or piercings.

If you are unsure whether you can use this device, please consult your doctor before use. 

Device care:

  • Ensure there is no obstruction of airflow through the ventilation slots of the device.
  • Store the device in dust free and dry space.
  • Do not expose device to direct sunlight or UV light for prolonged hours.

Caution:

  • Keep the device and the adapter dry at all times.
  • If the device or adaptor is damaged, do not touch the inner parts to avoid electric shock.
  • Water and electricity are a dangerous combination, hence do not use device in a wet environment.
  • The device is not intended for use by persons with reduced physical, sensory or mental capabilities, unless they have been given supervision or instruction concerning use of the device by a person responsible for their safety at all times.
  • The device is not intended for children 15 years and below.
  • Do not use the device if the light exit window is broken.
  • The light exit window can get very hot after use, do not touch the inner parts of the light exit window before it cools down.
  • For hygiene purposes, device should only be used by one person.
  • Device setting should be set as per recommended for each skin type. Using a higher setting can increase risk of skin reaction and side effects.
  • Do not look at the flash window directly while using the device. A protective eyewear is provided along with the device for your safety.
  • Use device in a well-lit room, so the flashes are less glaring in your eyes.
  • Switch off device after use.
  • Tanning with natural or artificial light might affect the sensitivity and colour of skin.
  • Before using the device, ensure that your skin is hair-free, clean and dry.
  • Do not treat the same skin area more than once during each session.
  • The device should not cause pain or discomfort, reduce the light intensity.

Device specifications

Product

Koizuma Hair Removal Device

Spectrum

>550nm

Model

DH5-IPL

Pulse Duration

0.9+/-0.2ms

Rated Input

AC100-240V/50-60Hz

Max Light Energy

7.92 – 15.31J

Rated Output

DC 12V, 2.5A

Operating Temperature

5°C - 25°C

Executive Standard

GH4706.1 GB4706.15

Operating Humidity

15% - 75%

Protection Against Electric Shock

II

Weight

209g

Protections rating

IP 30 (EN 60529)

Size

H179*W70*D35mm